HANVEY MOBILE MANUAL

Xantrex Inverter Settings Lead Acid

Troubleshooting

How To Check And Change Your Xantrex Inverter Settings:

  • A brief video on how to make sure your Xantrex inverter is setup correctly!
  • Note this should only be done if you are advised to do so by a Hanvey representative or if you are having power issues where you believe a faulty setting is at fault!
  • The inverter control panel is located above the driver's door.
  • Press the far right button (function) to turn on the backlight.
  • Press the function button until you see "System Status" in the top left of the screen.
  • Press the enter button to access this menu.
  • Scroll down until you have highlighted "FSW3012 00: Basic".
  • Press the enter button to access this menu.
  • Scroll down to the very bottom and highlight "Basic Settings".
  • Press the enter button to access this menu.
  • Scroll through the settings on this menu to verify they match the following:
    • Batt Type [Flooded]
    • Batt Capacity [880Ah]
    • Max Chg Rate [55%]*
      • Any value between 55 and 60 is acceptable here.
    • Charge Cycle [3Stage]
    • ReCharge Volts [12.5V]
    • AC In Breaker [10.0A]**
      • For vans without an Inline Tank Warmer, this should be set to 15.0A.
      • This will only apply to vans built prior to 2018.
    • Low Batt Cut Out [10.0V]
  • If a setting is not correct, scroll to it and press the enter button.
  • Use the arrow keys to set it to the correct setting.
  • Press the enter button once it is set to store the setting in the panel.
  • Once all the settings are verified, press the function button until you are back to the "System Status" screen.
  • Thank you so much for being the most important member of the Hanvey family!